The correct use of Pulse Oximeter in measuring oxygen status

Author: Luca Todani

This paper aims to promote a greater awareness of the importance of having an appropriate knowledge base before using pulse oximetry and to provide a The pulse oximeter, which is used for evaluating the oxygen status of patients in a variety of clinical settings, has become an increasingly common piece of monitoring equipment.

It provides continuous, non-invasive monitoring of oxygen saturation of hemoglobin in arterial blood. Its results are updated with each pulse wave.

Pulse oximeters do not offer information about hemoglobin concentration, cardiac output, the efficiency of oxygen delivery to the tissues, oxygen consumption, the sufficiency of oxygenation, or adequacy of ventilation. They do, however, provide an opportunity for deviations from a patient’s oxygen baseline to be noticed immediately, as an early warning signal to clinicians to help prevent the consequences of desaturation and detect hypoxemia before it produces cyanosis.

It has been suggested that the increase in the use of pulse oximeters in general wards could see it becoming as commonplace as the thermometer. However, the staff is reported to have limited education in the operation of the device and limited knowledge of how it works and what factors may affect the readings.

How does the pulse oximeter work?

Pulse oximeters measure the retention of explicit wavelengths of light in oxygenated hemoglobin as contrasted and that of diminished hemoglobin. Blood vessel oxygenated blood is red because of the nature of oxyhemoglobin it contains, making it assimilate light of specific wavelengths. The oximeter test has two light-radiating diodes (LEDs), one red and one infrared, situated on one side of the test.

The test is set on an appropriate piece of the body, more often than not a fingertip or ear projection, and the LEDs transmit light wavelengths through throbbing blood vessel blood to a photodetector on the opposite side of the test. Infrared light is consumed by the oxyhemoglobin; red light by the diminished hemoglobin. Pulsatile blood vessel blood amid systole makes a convergence of oxyhemoglobin the tissue, retaining progressively infrared light, and enabling less light to come to the photodetector. The oxygen immersion of the blood decides the level of light ingestion. The outcome is handled into a computerized presentation of oxygen immersion on the oximeter screen, which is symbolized as SpO2.

There are different makes and models of Pulse oximeters accessible (Lawton, 1999). Most give a visual advanced waveform show, a capable of being heard a presentation of blood vessel throbs and pulse, and an assortment of sensors to suit people paying little mind to age, size or weight. Determination relies upon the setting in which it is utilized. All staff utilizing the beat oximeter must know about its capacities and right utilization.

Blood vessel blood gas investigation is progressively exact; be that as it may, beat oximetry is considered adequately precise for most clinical purposes, having perceived that there are impediments.