What is Fire Alarm? How Fire, Smoke, Heat detection Systems Works?

Author: Vinaykumar Gattadi

A fire alarm system is used to detect and identify fire or fire in the building, fire alarms warn the peoples of the building about fire via a sound alarm. The main components of fire alarms are smoke detectors, heat detectors, gas detectors, manual call points also called ‘break glass’ a when a person detects a fire he can manually raise an alarm, bell or alarm sounders. The main advantage of fire alarms is an early warning, it has a capacity to save life and property, it has low cost and fire alarms can be placed in a preferred location.

Now a day’s fire alarm systems are of smart sensors, intelligent control panel, and integration with other building services.

Fire alarm is to detect fire and convert into electrical signal can operate the alarm.

When a fire occurs then the alarm system sends pulses through electrical circuits to the control panel to run optical and sound signals. The optical signal indicates.

Types of Fire Alarms Systems

There are two types of fire alarm systems are there they are

  1. Manual fire alarm systems
  2. Automatic fire alarm systems

Manual fire alarm systems:

This system works manually by a person pressing an alarm button. Manually call points are shared in all building sections. The alarm is processed by breaking the glass cover so that the signal is sent to the control panel. Fire alarms combine with the second electrical sources with the main source so the devices work in case of main source breaks.

Map of alarm devices share inside the building next to the main entrance because easy to identify the place of fire.

Automatic fire alarm systems:

Fire alarms can be used in places and halls where the occurrences of fire incidents are more. These systems operate by detecting the flames or heat. This system is automatic no need to depend on the human regarding operations. This system can detect fire in no time and reducing the size of damages.

Components of Fire Alarms System:

There are four components are there they are

  1. Sensors
  2. Controllers
  3. Alarms

Sensors:

Sensors are of different types and they are

Smoke Detector:

Smoke the detector works based on the optical rays. If there is a fire incident occurs, Smoke rises and crosses the optical ray then the alarm works. The distance between each detector should not be more than 7.5 meters.

Heat Detector:

Heat the detector works based on a heat sensor. When the temperature rises due to fire then the alarm works. The distance between each detector should not be more than 5.5 meters. There are two types of heat detectors they are which work at 60 C degree which is used in most of the applications and another one works at 90 C degree which is used in generator rooms.

Smoke detectors are better than heat detectors. Heat detectors are mostly used where smoke is normally such as Kitchens and parking garages.

Multi-Sensor:

Combination of smoke detector and heat, the detector is called Multi-sensor detector and this type of detector is more expensive in price, but it gives better results. Multi sensors work as an alternative to smoke detectors.

Beam Detectors:

Beam detectors are placed 5 meters high, it is the most expensive type which consists of transmitter and receiver. The receiver simply reflects the signal from the transmitter and receiver, then the alarm works. There are two types of beam detector they are 1) the distance between transmitter and receiver should not exceed 50 meters. 2) The distance between the transmitter and receiver should not exceed 100 meters.

Beam the detector should be installed on the highs from 6 meters to 10 meters and if the beam detector height is more than 10 meters then it won’t work when there is a fire.

Controllers:

Controllers are mediators between sensors and alarms. Every controller has Fire Alarm Control Panel (FACP). FACP consists of Monitor, PCB, and Battery. The monitor is to view the options and information. PCB is Printed circuit boards is an Input/output Electronic board. The battery is used to extend when the main power cut. The fire alarm system will work even when the power cuts.

There are two types of controllers are there they are conventional and addressable type.

Conventional Type:

Conventional type is the open-loop system it cannot detect fire in a room instead it will detect zone wise which consists of more than a room. For example, a building is divided into zones each zone consists of some rooms. If there is a fire in a room the controller cannot detect the room but it detects the only zone which contains the room. This type is less expensive.

Addressable Type:

Addressable type is a closed-loop system where it can detect fire in a room in any zone in the building. For example, a building is divided into some zones, every zone consists of a room and every room contains address. If any fire incident occurs in a room controller can detect the room because the address of the room appears on the controller monitor with the help of a microprocessor. This type is more expensive.

Alarms:

There are two types of alarms are there they are sound alarm and sound and light alarm. The sound alarm sounds like a bell, horn and like sirens. The light alarm is strobe light which lights like flash of the camera.

Conclusion

A fire alarms system is used to detect the fire and smoke. The fire alarm operates to alert people to leave the location where fire or smoke incident occurs and fire alarm will sound to notify the people to alert from the fire incident. Fire alarms can be used in homes, schools, churches and businesses and functions as a catalyst to saving lives. Many alarms sound like beep, horn, bell, and siren.

Brihaspathi provides fire alarm systems in Hyderabad to help People by saving their lives and properties. Brihaspathi trade-in sales and supply of latest and innovative fire alarm system Hyderabad. Each fire alarm system provides complete protection against fire incidents. Each fire alarm is designed to meet the specifications and fit small to large organizations. Brihaspathi Fire Alarm System Suppliers in Hyderabad offer advanced, intelligent and addressable fire control features.

Our experience with different clients tells us that, choosing the right fire protection solution means to guarantee complete protection for the facility. We are the best in providing fire alarm system in Andhra Pradesh and we provide fire control systems, and we supply supporting equipment that helps in emergency power shutdown management, and intrusion detection system.