Resolve the KVAR billing challenge with Messung & Janitza

Author: Messung Electrical Engineering

In the modern world of KWH billing to KVAR billing, Energy/Utility managers face many challenges. There are so many issues and problems that solving them is a daunting prospect.

Customers get served huge electricity bills and even penalties but don't know how to analyze them. Internal departments often complain of short circuits and sparking at junction boxes, or unstable power supply that damages critical electronic equipment. Energy/Utility managers are under constant pressure to provide clean, harmonic-free and transient-free power to the entire facility.

MAKE ELECTRICITY VISIBLE, TRACEABLE AND TREATABLE.

Messung, India's pioneer and leader in industrial automation, brings advanced energy management products & solutions from Janitza Electronics GmbH, Germany, for the benefit of Indian industry.

As their Mega Distributor for India, Messung presents Janitza's Class A power quality analyzers, devices and ISO 50001-certified GridVis power grid monitoring software - for continuous and reliable energy data management (e.g. ISO 50001), power quality monitoring and residual current monitoring. Janitza technology can help you improve power quality, maximize plant availability, save energy costs and penalties with reliable monitoring, error detection and extensive analyses for detailed insights.

ENERGY DATA TRANSPARENCY WITH JANITZA UMG 512-PRO

UMG 512-PRO is a Class A power quality analyzer that processes, visualizes and analyses data with the help of pre-installed Janitza APPs. The traffic-light principle in UMG 512-PRO makes complex power quality analyses, for example, understandable for everyone.

3 unbeatable advantages of UMG 512-PRO:

  • Reliably records, analyses and documents harmonics, unbalance, transients, voltage dips & swells, phase shifts and reactive power
  • Residual Current Monitoring (RCM) detects leakage currents in their initial stages before they cause system failures or fires
  • Comprehensive communication options enable cost-efficient and rapid integration into existing communication architectures.
  • CONTROL ENERGY CONSUMPTION WITH UMG 96-PA

    UMG 96-PA is a unique MID-compliant energy measurement device that offers four functions in one solution:

    Energy management system: for continuous energy monitoring and identification of potential savings to reduce costs

    MID compliant measurement:

    for legally secure accounting & energy acquisition

    Power quality: to provide secure, highly available power supply, avoid production downtime and maximise operating times/preventative maintenance

    RCM: continuous monitoring for protection against fires and other hazards, and increased system availability

    SAVE ENERGY WITH GRIDVIS

    Janitza's GridVis software is an open system offering future-proof solutions for connectivity. It enables graphic visualisation of data with free layout design and many application-oriented functions.

    It incorporates professional tools for evaluating all measurement and consumption data, and provides meticulous documentation with automatic email sending. Measured parameters can be analysed in order to detect possible production failures early and to therefore optimise your equipment's useful lives. Through alerting, GridVis ensures reliability, safety, and uptime.

    GridVis is the power grid monitoring software that combines 3 applications in one package: Energy Management(ISO 50001), Power Quality (EN 50160, EN 6100-2-4, IEEE 519, ITIC) and RCM.

    ADVANTAGES OFMESSUNG ENERGY MANAGEMENT SOLUTIONS

    Messung's Energy Management solutions are engineered to drive two main benefits for industry:

    Save money

    Messung's solutions will help clients save on the overall energy bill, the cost of energy per unit of production (especially important where the energy cost is a major element of their product cost), and on penalties which can be avoided

    Improve power quality

    For customers using sensitive equipment or high priority areas e.g. data centers, quality control laboratories, calibration centers, hospitals, R&D laboratories, Messung solutions can ensure power supply is without Harmonics, and free from Transients, Sag and Swell, Voltage fluctuations and interruptions.

    Messung solutions achieve this by enabling a detailed power quality audit and mutually discuss strategies to meticulously control Tariff charges, including KVAH/KVAR billing, MD, TOD, and many other critical parameters.

    By using Janitza's Class A power quality analyzer UMG 512 PRO at the PCC level and a number of UMG 509 QA, and UMG 96 PA at appropriate power consumption areas, and the GridVis EMS software; Messung provides complete visibility of the electrical usage in your organization.

    Messung's energy management solutions use world-class technology and accepted methods to:

  • Bring the Harmonics down to the minimum and hence provide safe and clean power to critical equipment
  • Keep the PF within the accepted range
  • Interlock major machines and processes using PLC based technology so that the power is used optimally
  • Use the TOD tariff to see that the maximum power is utilised at the least power tariff period
  • Implement a continuous monitoring system by using IOT and SCADA to see that if any of the precautionary measures are failing, they are detected and corrected in time
  • CONCLUSION

    For industrial and large energy consumers, Messung offers smart solutions to monitor and analyse power usage, detect areas of wastage or mismanagement, and implement correctives to improve and optimise the situation.Using Janitza's world renowned devices and their own PLC automation, Messung designs, installs and commissions intelligent energy management systems that deliver realbenefits for industrial and large energy consumers while helping them achieve their sustainability goals.

    Messung is the smart energy management system supplier for IoT based Smart Energy Monitoring besides low voltage power distribution systems, busbar systems, low voltage switchgear & control gear assemblies.