Directory Image
This website uses cookies to improve user experience. By using our website you consent to all cookies in accordance with our Privacy Policy.

High-speed centrifuge Technical performance

Author: Chason Chan
by Chason Chan
Posted: Apr 11, 2018

High-speed centrifuge Technical performance

The max speed is 12000rpm, and max capacity is 2000mlx4

It has micro-computer control, electronic lock and AC variable-conversion motor which delivers high torque.

Imported compressor unit with Non-CFC.refrigerant. It measures up to environmental standards.

The machine is programmable. The operation data can be stored automatically.

GL-12M has LCD and LED display. Touching panel makes the operation easy.

The real-time conversation of Speed and RCF is convenient for operation.

It has self-locking device, over-speed safety device, over-temperature safety device, imbalance safety device and automatic alarm device.

It has 10 files of acceleration and deceleration level for your choice.High speed centrifugal note:1. To ensure safety and centrifugal effects, the instrument should be placed on a sturdy, shock-resistant surface and ensure that all four legs are balanced.2. Before using the centrifuge, remove the foreign matter in the cavity of the centrifugal chamber, check if the rotor body is correctly installed in the rotor seat to ensure a good connection, the screws that connect the rotor and the shaft of the rotor. motor should tighten well.3. Strictly follow the rotor's allowable rotation speed setting of the high-speed centrifuge, and strictly exceed the maximum rotational speed specified by the rotor design.4. It is forbidden to use the rotor in an unbalanced way. The centrifuge tube must be placed symmetrically. It can not be used in a single tube. The solution in the tube must be uniform to ensure a balanced operation.5, no high-speed operation of the rotor is strictly prohibited.6. When removing the rotor from the high speed centrifuge, you must use the special handle provided by this machine. It is forbidden to pull the screw directly after the screw is loose, so as not to damage the flexible motor support.7. Check the rotor and centrifuge tube for cracks, corrosion marks and aging before use. If any should be replaced immediately, the use of a cracked or corroded rotor is strictly prohibited.8, check if the external power supply meets the requirements, the instrument is reliably grounded.9. The centrifuge should not move while the centrifuge is running. Do not open the lid of the door. Do not open the door cover when the motor and rotor have not stopped completely.10. After the centrifuge or high-speed rotor is deactivated for three months, it should run at low speed for 10 minutes before it is allowed to press the maximum speed of the rotor.11. Do not mix rotors from other units to avoid instrument damage and personal safety.12. Do not place a container full of liquid in the instrument. If the container is overturned, the liquid can enter the centrifuge and oxidizes the mechanical or electrical components.13. Once the separation of the high speed centrifuge has been completed, the instrument should be cleaned with a clean cloth. At the same time, turn off the power switch of the instrument and unplug the power cord.If you think our product is good, please click on the link to our website for more information about High-speed centrifuge.

About the Author

Prp is a topic that has been active in the beauty industry in recent years.

Rate this Article
Author: Chason Chan

Chason Chan

Member since: Apr 10, 2018
Published articles: 11

Related Articles