How to maintain your vfd control panel?

Author: Mayank Shah
by Mayank Shah
Posted: Jun 11, 2020

At Accupanels.com we see many VFDs and control panels that have encountered a shortened lifetime. Many of the issues we see are avoidable with proper maintenance. one among the simplest ways to urge the foremost out of your VFD instrument panel is to get the proper one to start with. ensuring your instrument panel has the proper enclosure, the right filtration/ventilation, and therefore the right electrical equipment will help to make sure its maximum lifespan.

There are three keys to maximizing the lifetime of electrical control equipment, especially VFDs. Keeping these three areas in mind will assist you get the utmost anticipation out of your electrical equipment.

Cool

Make sure that your VFD instrument panel is sized correctly and has appropriate cooling for its environment. this might include fans or air con (depending on the ambient temperature), the enclosure, and therefore the location of the VFD (indoor or outdoor).

Clean

VFD control panels will often got to run equipment in dirty environments. Choosing the proper VFD instrument panel with the right enclosure ratings and filters will help to stay the VFD as clean as possible. Later during this article we'll discuss the way to clean your electrical control equipment when a unclean environment has made its way inside the cupboard.

Dry

When we are handling electricity it's imperative to stay it dry. Letting your VFD instrument panel get wet is that the fastest thanks to destroy it. Take the time to pick the proper enclosure rating (NEMA 1, NEMA 3R, NEMA 4X, NEMA 12 then on) to make sure that the instrument panel will keep its contents dry and is acceptable for the environment.

Simple check-ups and maintenance

When maintaining your VFD instrument panel there are only a couple of things to think about. All of them are easy and straightforward, yet per annum we still see VFD control panels that require expensive repairs because simple and cheap maintenance was ignored.

Filters

Many VFD control panels will accompany filters. Check and alter these filters as required. How often these filters got to be changed will depend upon the environment that the instrument panel is working in. If you're placing a panel during a dusty or dirty environment, you would possibly want to think about purchasing a panel with filters installed outside (like those listed at rock bottom of the article). Some panels accompany washable poly filters (like our F3R panels). There in case, you only got to have them washed and dried regularly to stay the panel cool and clean.

At times, filters are located outside the panel for simple replacement.

Washable poly filter

cooling devices

Fans are often wont to cool the panel, but they're going to typically fail at some point. Some panels (like the one shown below) have redundant fans installed an honest decide to keep the panel cool just in case of fan failures. Whether it's redundant fans or not, it's good to urge within the habit of regularly checking the cooling devices to form sure they're functioning properly.

A panel with redundant fans just in case of fan failures

Routine visual inspections

VFD control panels are commonly located in remote areas or are often left during a mechanical room examined only a drag occurs. Taking the time to regularly check on your control panels can prevent from expensive repairs and unnecessary downtimes. Below is an example of a VFD instrument panel that went unattended until there was a catastrophic failure. We strongly recommend routine visual inspections outside and inside the panel because often an outdoor look might not reveal a drag.

How to clean your VFD instrument panel

Surely many of you've got seen compressed gas in handy cans otherwise you might even have a compressor at your job site. For the great of your control panels, resist the urge to use these instruments to wash your VFD instrument panel. Using compressed gas will actually push dust and dirt farther into the crevices and may be harmful to your instrument panel within the end of the day. The simplest tool to use when cleaning a VFD instrument panel may be a vacuum. this may allow all the dirt and debris to be faraway from the panel and every one of its parts, ensuring good electrical connections.

Making sure you're taking the time to properly look after your VFD Control Panel not only helps you get the utmost life out of your instrument panel, but it also helps to scale back downtime and creates a safer work environment. If you're a touch too late on the upkeep of your panels and have started trying to find a replacement, you'll inspect our quality VFD control panels below for various purposes.