Why Board Reports IN_PWR_ABN Alarm,After R_LOS Is Suppressed?
Posted: Sep 26, 2019
Issue Description
In an OSN project, the Huawei OptiX OSN 3500 and Huawei OptiX OSN 1500 form an SNCP ring. Three optical ports on the N1SLQ1 of the OptiX OSN 3500 are not used. Hence, the R_LOS alarm is suppressed for the three optical ports. Then, the IN_PWR_ABN alarm, however, is reported.
Alarm Information
Null
Handling Process
Suppress the IN_PWR_ABN alarm.
Root Cause
After a higher level alarm is suppressed, the lower level alarms that are suppressed by this higher level alarm are reported. For example, after the R_LOS alarm is suppressed, the IN_PWR_ABN alarm is reported.
Suggestions
When you suppress an alarm, note that the lower level alarms that are suppressed by this alarm will be reported.
Figure 1 shows the inter-board suppression relations among common alarms.
Figure 1 Inter-board alarm suppression relations
Figure 2 shows the suppression relations among key alarms.
Figure 2 Suppression relations among key alarms
Issue Description
In an OSN project, the OptiX Osn 3500and OptiX OSN 1500 form an SNCP ring. Three optical ports on the N1SLQ1 of the OptiX OSN 3500 are not used. Hence, the R_LOS alarm is suppressed for the three optical ports. Then, the IN_PWR_ABN alarm, however, is reported.
Alarm Information
Null
Handling Process
Suppress the IN_PWR_ABN alarm.
Root Cause
After a higher level alarm is suppressed, the lower level alarms that are suppressed by this higher level alarm are reported. For example, after the R_LOS alarm is suppressed, the IN_PWR_ABN alarm is reported.
Suggestions
When you suppress an alarm, note that the lower level alarms that are suppressed by this alarm will be reported.
Figure 1 shows the inter-board suppression relations among common alarms.
Figure 1 Inter-board alarm suppression relations
Figure 2 shows the suppression relations among key alarms.
Figure 2 Suppression relations among key alarms
Issue Description
In an OSN project, the OptiX OSN 3500 and OptiX OSN 1500 form an SNCP ring. Three optical ports on the N1SLQ1 of the OptiX OSN 3500 are not used. Hence, the R_LOS alarm is suppressed for the three optical ports. Then, the IN_PWR_ABN alarm, however, is reported.
Alarm Information
Null
Handling Process
Suppress the IN_PWR_ABN alarm.
Root Cause
After a higher level alarm is suppressed, the lower level alarms that are suppressed by this higher level alarm are reported. For example, after the R_LOS alarm is suppressed, the IN_PWR_ABN alarm is reported.
Suggestions
When you suppress an alarm, note that the lower level alarms that are suppressed by this alarm will be reported.
Figure 1 shows the inter-board suppression relations among common alarms.
Figure 1 Inter-board alarm suppression relations
Figure 2 shows the suppression relations among key alarms.