It has become common practice for internet service providers and server firms to require backup power in order to proceed with their runtime in case of a power outage. Power outage may be the result of a power-cut or a fault in the lines. It is during such times that the necessity of a UPS is most clear in people’s mind. With the assistance of a proper network UPS one can receive premium battery runtime and backup power. This is where the Eaton 9170 UPS comes in. The most fascinating fact about this UPS is that it adjusts and adapts well in whichever IT environment it is in. Eaton 9170 UPS has the most useful and undoubtedly the best backup sources that are suitable for each and every kind of critical environment.

FeaturesThis state-of-the-art UPS has the following unique features: • It has an N + 1 battery and power redundancy that efficiently eliminates the possibility of a single point of failure. • It has 3 kVA scalable design power and battery modules incorporated into it. This goes a long way in helping to increase a battery’s service life. • It has hot-swappable power and battery modules that are lightweight. • It has the capability to gather as much information as it can about critical parameters using an LCD screen. • Eaton 9170 UPS has a power rating of 3kVA, 6kVA, 9kVA, 12kVA, 15kVA and 18kVA. • Its input can accommodate 208V, 220V, 230V and 240V. • Its output can handle 120V, 208V, 220V, 230V and 240V. • Eaton 9170 UPS requires a frequency of 50/60 Hz. • This UPS is compatible with all operating systems and PCS currently available in the market. • It has an efficiency that is greater than 88% in double-conversion mode. • Eaton Powerware 9170 UPS has an efficiency that is greater than 84% in double-conversion mode but with isolated output. • It has efficiency that is greater than 96% in bypass mode with isolated output. Routine maintenanceEaton Powerware 9170 UPS system is properly designed to provide a long service life. However, this is heavily dependent on the routine maintenance performed on the UPS. The recommended routine maintenance schedule that should be carried out at least twice a year is as follows: i. The operating environmental conditions should be checked to ensure that it is cool, dry and clean. ii. The unit should be inspected and cleaned so often. iii. The MOV suppression pack should be checked regularly. iv. A system test should always be done on the UPS. v. The batteries ought to be checked all the time. vi. Connections should be checked and tightened so that there are no interruptions. vii. The power modules of the fan should be checked for proper operating conditions. viii. The displayed UPS readings should be checked against actual measurements and calibrated if necessary. ix. The values of the parameters on battery and in menu 3 online should always be checked and recorded.

The above routine maintenance should be carried out by a licensed technician who has some familiarity with the UPS. This is the only way you can avoid any dangers of damaging the UPS.Eaton Powerware 9170 support UPS is ideal for IT environments that are ever changing.

If you are looking for Eaton Uninterruptible Power Supply Online, then the author of this article recommends N1 Critical Technologies EATON-upssystems.

About the Author

If you are seeking Eaton Ups Service, the author of this article recommends N1 Critical Technologies.

Rate this Article
Leave a Comment
Author Thumbnail
I Agree:
Comment 
Pictures
Author: Robert Markham

Robert Markham

Member since: Jul 01, 2016
Published articles: 11

Related Articles